Будь ласка, використовуйте цей ідентифікатор, щоб цитувати або посилатися на цей матеріал: https://dspace.kmf.uz.ua/jspui/handle/123456789/4617
Назва: Development of toxicity tests for Polyurethane foams
Автори: Julie Mallouhi
Hornyák-Mester Enikő
Varga Miklós
Viskolcz Béla
Bela Fiser
Фішер Бейло
Fiser Béla
Szőri-Dorogházi Emma
Ключові слова: Polyurethane;Ecotoxicological assessment;Acute toxicity test;Sinapis alba;Escherichia coli
Дата публікації: 2024
Видавництво: Elsevier
Вид документа: dc.type.collaborative
Бібліографічний опис: In Heliyon. 2024. Volume 10., Issue 19. 12 p.
Серія/номер: ;Volume 10., Issue 19.
Короткий огляд (реферат): Abstract. Polyurethanes (PUs) are a special class of polymeric materials that differ significantly from most other types of plastic in many aspects. They can be utilized in a wide range of products, including paints, coatings, elastomers, insulators, elastic fibers, and foams. PU foams are especially important as part of various convenience products. PU products often end up in landfills when they are no longer useful and can release toxic compounds when damaged by humans or mi crobes. Therefore, the ecotoxicological assessment of PU foams is essential. In this paper, five PU foam samples were prepared with different NCO indices (NCO-0.8, 0.9, 1.0, 1.1, and 1.2) and together with the Control sample (a previously tested non-toxic foam sample) were applied to develop toxicity tests procedure, while intentionally prepared Toxic foam has been used to verify the accuracy of the developed testing procedure. Two test organisms were successfully applied, Sinapis alba (white mustard) seeds and Escherichia coli (non-pathogenic) bacterial model organ isms, and toxicity tests were adapted for the examination of PU-derived substances. Regarding Sinapis alba test, the highest NCO index (NCO-1.2) significantly reduced root length by 9.8 % compared to the Control sample. In the bacterial test, it was observed that the samples containing NCO-1.1 and NCO-1.2 had lower colony numbers (5.0 × 108 and 4.9 × 108 CFU/mL respectively) in comparison to the Control plate (9.6 × 108 CFU/mL). All in all, two toxicity tests were suc cessfully adapted for PU foams, and both are applicable in their ecotoxicological assessment.
URI (Уніфікований ідентифікатор ресурсу): https://dspace.kmf.uz.ua/jspui/handle/123456789/4617
ISSN: 2405-8440 (Online)
metadata.dc.rights.uri: http://creativecommons.org/licenses/by-nc-nd/3.0/us/
Розташовується у зібраннях:Fiser Béla

Файли цього матеріалу:
Файл Опис РозмірФормат 
Fiser_et_al_Development_of_toxicity_tests_for_Polyurethane_foams_2024.pdfIn Heliyon. 2024. Volume 10., Issue 19. 12 p.2.05 MBAdobe PDFПереглянути/Відкрити


Ліцензія на матеріал: Ліцензія Creative Commons Creative Commons